Thursday, March 3, 2011

4000LPH automatic brackish water desalination/water desalination plant

4000lph B2K water treatment for municipal sewage water treatment
Brief introduction:

The output capacity of this system is designed for the raw water of 25°C. If the temperature of the raw water is higher or lower than 25°C when actual operation, the capacity is subject to change accordingly. In addition, the change of the quality of the raw water will also influence the output quality and capacity, which will be explained separately later.

The system is composed of three parts:RO filtration,fresh water replacement and electrical control.

The feed water was firstly filled into sediment filter, then feed into the RO system after pressurized by high pressure pump. The permeate water was feed into the permeat tank and the concentrate water was discharged or recovered. When stop operation, the equipment should be cleaned by fresh water replacement system.

FEATURES
Automatic control system,easy operation and maintenance
Well-chosen material,precise design of technics,multi-faceted quality inspection,detailed system instruction
High salt rejection and recovery rate,stable performance,long lifetime,low operation and maintencance cost.
Unique fresh water automatic replacement system. The equipment will replace concentrate in membrane to reduce pullution when system stops.

B2K7 seires---apply to raw water≤7000ppm

No
Spec.
GPD
T/H
Designed Recovery
No. of 4” Element
Membrane Vessel Spec.
Operating
Pressure
Driving Moror
1
1500GPD
1500
0.25
15%
1
4”*40”
19.3
3.0
2
3000GPD
3000
0.50
42%
3
4”*40”
17.0
2.2
3
4500GPD
4500
0.75
50%
4
4”*40”
19.3
3.0
4
6000GPD
6000
1.00
50%
5
4”*40”
20.0
3.0
5
9000GPD
9000
1.50
45%
7
4”*40”
20.0
5.5
6
13000GPD
13000
2.00
49%
10
4”*80”
19.3
5.5

B2K9 seires---apply to raw water≤9000ppm

No
Spec.
GPD
T/H
Designed Recovery
No. of 4” Element
Membrane Vessel Spec.
Operating
Pressure
Driving Moror
1
1500GPD
1500
0.25
26%
4”*2
4”*40”
15.6
2.2
2
3000GPD
3000
0.50
42%
4”*3
4”*40”
9.9
2.2
3
4500GPD
4500
0.75
40%
4”*4
4”*40”
20.8
3.0
4
6000GPD
6000
1.00
28%
4”*5
4”*40”
20.0
5.5
5
9000GPD
9000
1.50
33%
8”*2
8”*40”
18.1
5.5
6
13000GPD
13000
2.00
40%
8”*3
8”*40”
17.8
5.5

No comments: