Tuesday, May 10, 2011

Wire Anode

The wear rate of the anode is extremely low and uniform and between 1 and 6 milligrams/ampere-year.
Parameter
Diameter (mm)
Diameter Tolerance (mm)
Titanium
Copper
Surface Area (m2/m)
Weight ( g/m )
Thickness (mm)
Diameter (mm)
1.5
+0.15 -0.00
0.2
1.1
0.0047
12.2
3.0
+0.28 -0.00
0.2
2.6
0.0094
66.4

The coating used on wire is suitable for most cathodic protection applications,
but current output varies with application.
Wire Anode Aplication
Canistered anodes
Continuous horizontal groundbed
Discontinuous vertical groundbed
Above ground storage tanks
Underground storage tanks
Electrical cable shielding
Water storage tanks
Water treatment equipment