Saturday, February 5, 2011

wind and solar controller

1.wind and solar controler
2.low vlotage charge
3.CE certificate.
4.2 years warranty
5.remote monitoring,LCD
wind and solar controller,wind and solar hybrid controller,wind solar controller,hybrid controller,wind solar street light controller,wind solar charge controller.solar charge controller,wind controller
Model WWS200A-220 WWS200A-240 WWS200A-360
Rated Wind Turbine Maximum Power 20KW
Rated Battery Voltage 220V 240V 360V
Rated Wind Turbine Maximum Input Current 150A 130A 90A
Wind Turbine Maximum Input Power 30KW 30KW 30KW
Unload Voltage(factory default) 252 V 280 V 420 V
Unload Current(factory default) 72A 72A 36A
PV Maximum Charge Current 20A 20A 20A
Temperature Compensation -5mv/°C/2V(Over discharge protection,over-discharge recovery voltage ,unload voltage compensation) --5mv/°C/2V(Over discharge protection,over-discharge recovery voltage ,unload voltage compensation)
Unload Mode PWM
Display LCD
Display Parameters Battery Voltage,Wind Turbine Voltage,PV Voltage,Wind Turbine Current,PV Current,Wind Turbine Power,PV Power,Under-voltage,short-circuit,Night.Etc
Range of working temperature &Humidity -20~+55°C/35~85%RH(Without Condensation)
Protection Mode Solar cells reverse charging,Solar cells anti-reverse,battery over charge,battery over-discharge,battery anti-reverse,over load,load short-circuit,lighting,wind turbine current limitting,wind turbine automatic brake and manual brake.
In order to give our customers better serve, we can adjusted configuration and parameters according to the customer’s request
Optional function
1 Communication function Can chose RS232 communication interface,Provide remote monitoring software along with the controller.After monitoring software installation,users can check and set parameters through te software.At the same times,users can put the parameters which record in the system operation process into Excel to save.
2 Low voltage charge function To improve the traditional controller’s insufficient,which is only when the fan or solar panels’s voltage higher than the battery’s voltge can be charging.Now the system can be charging from a low voltage.If the users chose the communication function ,they can set the charge voltage through the software.
3 Remote control system Users can chose GPRS wireless communicationsfunction,serial communication server system.Users can control some systems through one computer at the same time.