Model SPWWS30A-48 WWS20A-96 WWS20A-120 WWS20A-220 WWS20A-240
Rated Wind Turbine Maximum Power 2000W
Rated Battery Voltage 48V 96V 120V 220V 240V
Rated Wind Turbine Maximum Input Current 60A 30A 20A 10A 10A
Wind Turbine Maximum Input Power 3000W 3000W 3000W 3000W 3000W
Unload Voltage(factory default) 56V 112 V 140V 252 V 280 V
Unload Current(factory default) 36A 18A 18A 18A 18A
PV Maximum Charge Current 10A 10A 10A 10A 10A
Temperature Compensation -5mv/°C/2V(Over discharge protection,over-discharge recovery voltage ,unload voltage compensation) --5mv/°C/2V(Over discharge protection,over-discharge recovery voltage ,unload voltage compensation)
Unload Mode PWM
Display LCD
Display Parameters Battery Voltage,Wind Turbine Voltage,PV Voltage,Wind Turbine Current,PV Current,Wind Turbine Power,PV Power,Under-voltage,short-circuit,Night.Etc
Range of working temperature &Humidity -20~+55°C/35~85%RH(Without Condensation)
Protection Mode Solar cells reverse charging,Solar cells anti-reverse,battery over charge,battery over-discharge,battery anti-reverse,over load,load short-circuit,lighting,wind turbine current limitting,wind turbine automatic brake and manual brake.
In order to give our customers better serve, we can adjusted configuration and parameters according to the customer’s request
Optional function
1. Communication function Can chose RS232 communication interface,Provide remote monitoring software along with the controller.After monitoring software installation,users can check and set parameters through te software.At the same times,users can put the parameters which record in the system operation process into Excel to save.
2. Low voltage charge function To improve the traditional controller’s insufficient,which is only when the fan or solar panels’s voltage higher than the battery’s voltge can be charging.Now the system can be charging from a low voltage.If the users chose the communication function ,they can set the charge voltage through the software.