1.wind solar hybrid street light controler
2.low vlotage charge
3.CE certificate.
4.2 years warranty
5.remote monitoring,LCD
wind solar hybrid street ligh controller,wind&solar hybrid controller,high performance wind solar hybrid controller,wind solar hybrid streetlight controller.hybrid controller,streetlight controller.
The wind&solar hybrid street light controller is used to control the wind power charging battery under constant voltage. In addition, it includes solar charging control, which makes it good for wind/solar hybrid application.
1-Low Voltage Charger
2-Remote Monitory and Control
3-LCD display
4.
Manual brake switch
:At the right side of the controller, there is a manual brake switch. If the switch is turned to the ‘BRAKE’ position, the wind turbine will be manually stoped. In normal situation, the switch should be turned to the ‘RUN’ position.
5.
"TIMER”
: which is used set up the time, the four 1,2,3,4 switch on behalf of 1 hour, 2 hours, 4 hours and 8 hours. For example,if you want set up 5 hours,you can switch “1” and ”3” to 'ON' position,
6.
"LIGHT ADJUST"
: regulating the "LIGHT ADJUST" potentiometer can set up light control point. For example, if you want illumine at the higher light of the circumstances, you can adjust the anti-clockwise potentiometer. On the other hand, you can adjust the anti-clockwise potentiometer.
7."NIGHT"
:which indicate it is night now, at this situation,the “DC 1 output” and “DC 2 output” terminals will have DC output.
8."UNDER VOLTAGE"
: which indicate the battery voltage is lower than " Under Voltage Point ".at this situation, the “DC 1 output” and “DC 2 output” terminals will stop DC output.when the battery voltage is higher than " Under Voltag Recovery Point ", the" UNDER VOLTAGE " will lights off automatically ,and “DC 1 output” and “DC 2 output” terminals will have DC output.
9."CHARGE"
:which indicate the controller is in the charging state.
Model
WWS06A-24
Rated Battery Voltage
24V
Rated Wind Turbine Voltage
28VDC
Rated Wind Turbine
Maximum Power
600W
Input Impedance Range
2~30Ω adjustable3 Ω
Input Current
0~40A
Rated Wind Turbine
Maximum Input Power
1000W
Wind Turbine Charge Voltag
( Factory Default)
Continuous Adjustable 4V
Unload Voltage
(Factory Default)
26v~30V adjustable 27V
Unload Current
(Factory Default)
0~20A adjustable 8A
Wind Turbine Over Speed
( Factory Default)
0~600rmp adjustable ,over-rotate speed 10 minutes later , recover to 500rmp automaticlly
Rated PV Maximum Power
300W
Rated PV Rated Voltage
34V
PV Maximum Current
10A
Battery Over-Discharge
Protection Voltage
20v~24V adjustable 22V
Battery Over-Discharge
Recovery voltage
22v~26V adjustable 24V
Output Protection Voltage
32V
Temperature Compensation
-5mv//2VOver-Discharge Protection, over-discharge recovery voltage unload voltage compensation
PV Voltage Of Light Control On
2~6V adjustable 2V
PV Voltage Of Light control Off
3~8V adjustable 3V
Line 1 Rated Output Current
10A
Line 2 Rated output Current
10A
Line 1 Output Mode
(Factory Default )
Seven Modes ( Light Control on and light controll off)
Line 2 Output mode
(Factory Default)
Seven Modes ( Light Control on and time control 5 hours)
Display Mode
LCD
Display Parameters
Battery Voltage ,Wind Turbine Voltage,PV Voltage,Wind Turbine Current, PV Current,Wind Turbine Power,PV Power.Ove-Voltage,Under-Voltage.Over-load, short circuit.Etc
RS232C (RS485
Range of Working Temperature &Humidity
-20°C~+55°C/35~85%RHWithout Condensation
15mA(with 485,100mA interface)
No comments: